Por favor, use este identificador para citar o enlazar este ítem: https://cir.cenieh.es/handle/20.500.12136/511
Título: Quantitative assessment of interproximal wear facet outlines for the association of isolated molars
Autor: Benazzi, Stefano
Fiorenza, Luca
Katina, Stanislav ‎
Bruner, Emiliano
Kullmer, Ottmar
Palabras clave: Dental remains;3D digital models;Elliptic fourier analysis;Geometric morphometrics
Fecha de publicación: feb-2011
Editorial: Wiley
Citación: American Journal of Physical Anthropology, 2011, 144 (2), 309-316
Resumen: The determination of the minimum number of individuals can be very challenging, especially in an assemblage of fragmentary bones and isolated teeth. Similarities in tooth morphology, degree of wear, and interproximal wear facets (IPWF) are generally used to associate isolated teeth qualitatively. However, no quantitative method has yet been established for an objective identification and matching of isolated tooth crowns. In this study, we analyze the IPWF morphology of adjacent mandibular molars (17 M1/M2 pairs), applying both qualitative and quantitative methods to test a reproducible approach for crown association. The surfaces of distal (for M1) and mesial (for M2) IPWF were surface‐scanned and digitally selected. Three‐dimensional (3D) and two‐dimensional (2D) outlines of IPWF were analyzed using elliptic Fourier analysis (EFA) and geometric morphometrics methods (GMM). Additionally, teeth were qualitatively associated by visual evaluation of the IPWF outline and by physical matching. Unsatisfactory results with less than 50% of tooth pairs correctly associated were obtained by using both methods, shape analysis (digital approach) and the visual evaluation (qualitative assessment) of the IPWF outline. The physical matching of the crowns showed highly variable accuracy ranging between 53% and 77%. The quantitative form‐space analysis of 2D IPWF outlines provided the best results (82% of correctly associated teeth), but no statistically significant differences were recorded when compared with the manual matching. Since three tooth pairs out of 17 could not be quantitatively associated, we suggest that the quantitative analysis of IPWF should be used only in addition with other approaches.
URI: http://cir.cenieh.es/handle/20.500.12136/511
ISSN: 0002-9483
1096-8644
DOI: 10.1002/ajpa.21413
Versión del Editor: https://doi.org/10.1002/ajpa.21413
Tipo: Article
Aparece en las colecciones: Paleobiología

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Quantitative assessment of interproximal wear facet outlines for the association of isolated molars_Benazzi_et_al_2011.pdf
  Restricted Access
367.53 kBAdobe PDFVisualizar/Abrir  Solicitar copia


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.